Scope of Work
Assessment of the concrete caisson AC4 to determine the internal structural condition of the pre tensioned strand wires.
Diving Tasks:
- Identification of the cutting areas on the caisson concrete surface.
- Cut the concrete windows to expose the strand wire conduits using precision cutting technology.
- Cut a window on the metal conduits.
- Remove the filling concrete around the strand wires by hydro blasting.
- Expose the strand wires and inspect for structural integrity.
- Cut samples of the strand wires for laboratory analysis.
- Inspect the sour mattresses around the caisson to determine the overall condition (Berth 2 northern caisson and MC3).
Get In Touch